Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Rev. Col. Bras. Cir ; 45(1): e1345, fev. 2018. tab, graf
Article in English | LILACS | ID: biblio-956540

ABSTRACT

ABSTRACT Objectives: to assess the degree of patient satisfaction after undergoing breast augmentation and compare three different, easy, inexpensive and universal methods of preoperative choice of breast implant volume. Methods: a prospective study was carried out at University Hospital Pedro Ernesto of State University of Rio de Janeiro, in 94 women from Rio de Janeiro, aged 18 to 49 years, submitted to breast augmentation mammaplasty with breast implant due to hypomastia. All implants were textured, with a round base and high projection and were introduced into the retroglandular space through an inframammary access. The patients were divided into three groups: Control, Silicone and MamaSize®, with 44, 25 and 25 patients, respectively. Satisfaction questionnaires were applied in the pre and postoperative periods by the same evaluator, through the visual analogue scale, in which '0' meant very unsatisfied and '100' very satisfied for the four variables: shape, size, symmetry and consistency. The degree of satisfaction with the surgical scar was also assessed in the postoperative period. Results: when the preoperative and postoperative satisfaction levels were compared, there was a difference in all variables for the three groups, with statistical significance. However, when the postoperative data were compared with each other, there was no significant difference. The degree of satisfaction with the surgical scar was high. Conclusion: the augmentation mammaplasty with breast implant had a high index of satisfaction among patients. However, there was no difference in the degree of satisfaction in the postoperative period between the three methodologies of breast volume measurement.


RESUMO Objetivos: avaliar o grau de satisfação de pacientes submetidas à mamoplastia de aumento e comparar três métodos diferentes, fáceis, baratos e universais, de escolha pré-operatória de volume de implante mamário. Métodos: estudo prospectivo, realizado no Hospital Universitário Pedro Ernesto da Universidade do Estado do Rio de Janeiro, em 94 mulheres naturais do Rio de Janeiro, com idades entre 18 e 49 anos, e submetidas à cirurgia de mamoplastia de aumento com implante, por hipomastia. Todos os implantes eram texturizados, com base redonda e projeção alta e foram introduzidos na loja retroglandular, por via inframamária. As pacientes foram divididas em três grupos: Controle, Silicone e MamaSize®, com 44, 25 e 25 pacientes, respectivamente. Foram realizados questionários de satisfação nos períodos pré e pós-operatórios pelo mesmo avaliador, através de escala analógico-visual, em que 0 significava muito insatisfeita e 100 significava muito satisfeita para as quatro variáveis: forma, tamanho, simetria e consistência. No período pós-operatório avaliou-se também o grau de satisfação com a cicatriz cirúrgica. Resultado: quando comparados os graus de satisfação do pré-operatório com os do pós-operatório, houve diferença em todas as variáveis dos três grupos, com significância estatística. Entretanto, quando comparados os dados dos pós-operatórios entre si, não houve diferença significativa. O grau de satisfação com a cicatriz cirúrgica foi elevado. Conclusão: a mamoplastia de aumento com implante teve um grande índice de satisfação entre as pacientes. No entanto, não houve diferença no grau de satisfação no período pós-operatório entre as três metodologias de mensuração de volume mamário.


Subject(s)
Humans , Female , Adolescent , Adult , Young Adult , Prosthesis Design , Breast Implants , Patient Preference , Prospective Studies , Patient Satisfaction , Middle Aged
2.
Rev. Col. Bras. Cir ; 44(5): 498-504, Sept.-Oct. 2017. tab, graf
Article in English | LILACS | ID: biblio-896618

ABSTRACT

ABSTRACT Objective: to evaluate the effects of increasing pressures on the cutaneous blood flow in the skin of pigs. Methods: we conducted an experimental study in pigs submitted to subcutaneous magnetic implants (n=30). After healing, were applied external magnets with varying magnetic forces to the skin, generating compression. We evaluated the cutaneous circulation of the skin under compression by the Laser Speckle Contrast Imaging (LSCI) technique. We measured the depth of the implants by ultrasonography, and applied computational simulations to the calculation of the different pressure values, considering the different distances between implants and external magnets. Results: nineteen implants presented complications. The remaining 11 were submitted to different magnetic compression forces and perfusion analysis. Two linear regression models showed an inverse correlation between exerted pressure and cutaneous perfusion, with significant variation, mainly in the initial pressure increases, of up to 20mmHg. Conclusion: The main reduction in cutaneous blood flow resulted from initial increases of up to 20 mmHg. The results suggest that tissue ischemia can occur even in low-pressure regimes, which could contribute to the appearance of skin lesions, particularly ulcers related to medical devices.


RESUMO Objetivo: avaliar os efeitos de pressões crescentes exercidas sobre a pele de porcos no fluxo sanguíneo cutâneo. Métodos: estudo experimental em porcos submetidos a implantes magnéticos subcutâneos (n=30). Após a cicatrização, foram aplicados sobre a pele, ímãs externos com forças magnéticas variadas, gerando compressão. A circulação cutânea da pele submetida à compressão foi avaliada pela técnica Laser Speckle Contrast Imaging (LSCI). A profundidade dos implantes foi medida por ultrassonografia, e simulações computacionais foram aplicadas para o cálculo dos diferentes valores de pressão, considerando-se as variadas distâncias entre implantes e ímãs externos. Resultados: dezenove implantes apresentaram complicações. Os 11 restantes foram submetidos à diferentes compressões magnéticas e análise de perfusão. Dois modelos de regressão linear mostraram uma correlação inversa entre pressão exercida e perfusão cutânea com variação significativa principalmente nos acréscimos iniciais de pressão até 20mmHg. Conclusão: a principal redução do fluxo sanguíneo cutâneo resulta dos acréscimos iniciais de pressão de até 20mmHg. Os resultados sugerem que a isquemia tecidual pode ocorrer mesmo em regimes de baixa pressão, o que poderia contribuir para surgimento de lesões de pele, particularmente as úlceras relacionadas a dispositivos médicos.


Subject(s)
Animals , Pressure/adverse effects , Skin , Regional Blood Flow , Swine
SELECTION OF CITATIONS
SEARCH DETAIL